Respiratory protection kit for 1 person with a full-face mask, ambient air pump & 50 feet, Allegro.
Allegro respiratory protection kit for one worker included: one low-pressure air source powered air-supply pump, one 50-foot-long hose and one full-face mask respirator, one size fit most (medium/large).
Code of the manufacturer Allegro: 9200-01.
This kit offers an all-set configuration to provide respiratory protection for one person. The pump is designed to transfer breathable air from an uncontaminated location to a worker who requires supply air. The ambient air pump connects to a standard power outlet, eliminating the need for special wiring and electrical compatibility issues. In addition, it can be easily transported from one job site to another.
This set contains:
For more specific information about the products included in this set, consult the product sheet by clicking on the product code in green.
Application:
This type of respiratory protection is recommended for work that will release solid and liquid particles into the air or work in environments where you find contaminants and/or biological particles in the air. The air supply system is required when the worker is in the presence of a contaminant that cannot be filtered by cartridges or filters.
Restriction:
You should not use a respirator when a beard is visible. Indeed, facial hair or any other condition that may prevent direct contact between the edge of the mask and the face may compromise a worker’s safety by not fully protecting him.
This kit offers a protection factor of 1000 NIOSH approved when you fully use all components designated by the manufacturer Allegro. You must check the level of respiratory risk associated with its use. The manufacturer has designed its products for environments with contaminant concentrations that do not exceed the limit that results in the immediate death of the worker (IDLH). This must be taken into account if the pump stops working. In addition, be sure to choose the location of your air source wisely because the pump is designed to transfer breathing air from an uncontaminated area to a worker. This kit offers a protection factor up to 1,000 times the exposure limit allowed by the CNESST or any other applicable government regulation. This kit is not recommended for sandblasting work. Do not use this respirator kit in areas where there is a risk of oxygen deficiency.
Maintenance and service life:
Mask maintenance:
This kit is reusable as long you provided the maintenance and storage according to the rules. Allegro recommends that you always inspect your mask before using it, clean it after using it, and keep it in its packaging when it is not in use. When cleaning, you should not use solvents since they can weaken some components of the mask, which can affect its effectiveness.
Pump maintenance:
The ambient air pump must not be fed to a generator. To avoid damaging the pump, we recommend that you attach the hose and the face part before starting it. Replace the inlet (RA9700-07) and exhaust (RA9700-02) filters after 200 hours of use. Replace carbon vanes around 400 to 500 hours of use (RA9700-41S).
Hose maintenance:
This hose could be washed by hand with cold or warm water and a mild detergent, thoroughly rinsed the inner part of the hose to remove traces of soap. It must also be dried in the open air away from the sun’s rays.
Suggestions:
Also take care to provide you with spare parts for the full-face respirator such as: the exhalation valve (RA9901-07), the inhalation valve (RA99901-03B) and peel-off to protect your visor (RA9901-25). And why not the parts of engine maintenance: the inlet filter (RA9700-07) and exhaust filter (RA9700-02), carbon vanes (RA9700-41S). Please note that his items are available only on special order only, the supply may vary from 2 to 3 weeks.
Possible other configurations:
The RA9806 (A-300) pump offers the ability to be configured with different size hoses as well as with other facial parts. You can choose air supply hoses of 25, 50 or 100 feet (RA9100 and RA9100-100), choose up to 1 type respirator half mask (RA9920) or full-face mask (RA9901). By cons you cannot use a hood.
To Consider Before Buying:
If you chose this specific model of respiratory protection, it is to protect a worker with a full-face respirator. You must remember that if you intend this kit to a man it must be finely shaved before using it. From experience we know that this requirement prescribed by standards (CSA and NIOSH) and by government agencies is very difficult to obtain daily. Your challenge will be to require the male worker to be finely shaved and to monitor daily or to opt for a hood. The problem with this model pump is that it cannot provide breathable air to a worker equipped with a hood. The capacity of the pump does not allow it. To obtain a powerful enough pump to feed a worker equipped with a hood you must choose the pump (RA9821) or the kit with hood (RA9220).
For more technical details, please refer to the attached PDF documents on” Download “tab under ‘More info’ tab.
Data sheet
You might also like