- New
Pack of 25 Brady 65444 B-853 cardstock lockout tags with the English message DANGER DO NOT OPERATE Electricians At Work. The front takes the name and date of the authorized person; the back states that only the individual who signed may remove the lock and tag. Intended for indoor use with no chemical exposure, they attach through a 0.38 in hole, with no grommet. The pack includes 25 tags and 25 cotton tie strings for attachment.
Delivery time: 14 to 17 business days.
Brady model 65444: B-853 cardstock lockout tag with the English message DANGER DO NOT OPERATE Electricians At Work, with a back that reserves removal for the signer.
On a locked-out electrical panel, everyone must understand who is working and who alone may remove the device. The front announces that electricians are at work; the back confirms that only the individual who signed the tag may remove it. The text is printed in English only.
| Feature | Detail |
|---|---|
| Manufacturer | Brady |
| Model | 65444 |
| Material | Cardstock (Brady B-853) |
| Front message | DANGER DO NOT OPERATE Electricians At Work |
| Text language | English only, front and back |
| Sold by | Pack of 25 |
| Colour | White, red and black |
| Face of one tag | 3 in / 7.62 cm X 5.75 in (5-3/4 in) / 14.61 cm |
| Thickness of one tag | 10 mils |
| Opening | 0.38 in / 0.97 cm, no grommet |
| Use | Indoor only; not recommended for chemical exposure |
| Service temperature | -40 °C to 90 °C / -40 °F to 194 °F |
| Country of origin | Mexico |
| Weight of the pack of 25 | 0.33 lb / 0.15 kg |
The weight shown is that of the pack of 25, not of one tag. The height, length and width in the product features describe one tag laid flat.
Apply the tag with the padlock on the breaker, disconnect switch or enclosure that the electrician has isolated. The electrician writes their name and the date on the front and signs the tag; nobody else may remove it. On the back, the Remarks area records the circuit or the nature of the work. B-853 cardstock is intended for indoor, temporary use. The tag informs; the padlock prevents re-energizing.
Fill out the tag before applying it, keep it dry and replace it as soon as it becomes illegible or damaged. Plan for a new tag for each job.
DANGER DO NOT OPERATE Electricians At Work forbids running the equipment while electricians are working on it. The text is in English only.
The back states that the energy source is locked out and that only the individual who signed the other side may remove the lock and tag. A Remarks area completes it.
No. Brady recommends this cardstock for indoor use only and does not recommend it for chemical exposure.
Pass the padlock shackle or a tie through the 0.38 in hole; this model has no grommet. The pack includes 25 tags and 25 cotton tie strings for attachment.
The face measures 3 in / 7.62 cm X 5.75 in (5-3/4 in) / 14.61 cm, with a thickness of 10 mils.
For the electrician identifying an isolated circuit, plan according to the assessed risk for Pro SKG/PXNE gloves from the ParaActiv (GSKGPXNE) range, designed against electric arcs, an MSA V-Gard type 1 class E helmet (TA84) with a 4-point suspension, 3M SecureFit SF602 glasses (YASF602) with an anti-fog lens, then 3M UltraFit corded earplugs (OA4004) or, as another choice, PELTOR X4A over-the-head earmuffs (OPX4A).
To complete the lockout, the Master Lock 406 padlock with a nylon (CA1ZKD1) shackle is keyed different. The red American Lock A1106RED aluminum (CA1ARG) padlock has a 1/4 in boron steel shackle. For a French (CAET5) instruction, the tags bear the message "DANGER NE PAS OPÉRER" and are sold in packs of 25. Select their material for the work environment and the resistance ratings shown on their product page. Check the shackle diameter and padlock fit in the isolating device. These separately sold accessories are used under your energy isolation and verification procedure.
Data sheet
Specific References
You might also like