- New
This item is not stocked: allow 14 to 17 days for delivery.
Brady 170379 lockout cable in red nylon, 164 ft (50 m) long and 0.125 in (3.18 mm) in diameter, sold on its own. Nonconductive, it is well suited to electrical lockout and offers excellent chemical, corrosion and temperature resistance. It has no loop at its ends, so lengths can be prepared for each job. It is used with an all-purpose cable lockout device. Device and padlock sold separately.
Brady model: 170379.
This item is not stocked: allow 14 to 17 days for delivery.
This all-purpose nonconductive red nylon cable is sold on its own, without device or padlock. Its 164 ft (50 m) make it possible to prepare lengths suited to each job, since it has no loop at its ends. The Brady technical data sheet dated 05/05/2022 lists it as a replacement cable for the all-purpose device: the device (CACC170377) sold without cable is the compatible device, offered separately. Its 3.18 mm diameter falls within the 3 to 5 mm range accepted by this device.
| Feature | Detail |
|---|---|
| Manufacturer | Brady |
| Model | 170379 |
| Material | Nylon |
| Length | 164 ft (50 m) |
| Diameter | 0.125 in (3.18 mm) |
| Service temperatures | -40 to 212 °F (-40 to 100 °C) |
| Intended use | Replacement cable for the Brady 170377 all-purpose device (sold separately) |
| Packaged dimensions | 6.3 X 6.3 X 4.6 in |
| Weight | 0.168 lb (76 g) |
| Colour | Red |
| Sold by | Unit |
| Country of origin | China |
The cable suits maintenance departments that prepare their own lengths for an all-purpose cable lockout device, especially for electrical lockout: several breakers on a panel, neighbouring disconnects. Follow the facility's written lockout program.
Cut the desired length, thread the cable through the energy isolation point and then through the device, and pull it tight before applying the padlock. Inspect the cable before each use and take it out of service if it is frayed, crushed or cut.
No. The cable is sold on its own; it is used with an all-purpose cable lockout device and a padlock, sold separately.
The Brady technical data sheet lists it as a replacement cable for the all-purpose lockout (CACC170377), which accepts cables from 3 to 5 mm in diameter.
Yes. The manufacturer intends it for electrical lockout applications.
164 ft (50 m) long and 0.125 in (3.18 mm) in diameter.
The manufacturer states service temperatures from -40 to 212 °F (-40 to 100 °C).
For the electrician locking out several breakers, plan for 3M Centurion splash goggles (YG454), SuperiorTouch nylon knit gloves (GS13GPU) with polyurethane coating, an Okanagan cap-style type 1 class E hardhat (TA14FS), MAX LITE 30 dB disposable earplugs (OA1102) and a black Pioneer 7729 arc-rated vest (V7729).
To complete your lockout equipment, the Master Lock keyed-alike padlock (CA1M) completes the device. The French DANGER ÉQUIPEMENT VERROUILLÉ tags (CAET6) are sold in packs of 25. For a breaker panel, the Brady oversized circuit breaker (CAC65329) lockout and the Brady flip (CAC65397) cover circuit breaker lockout fit on the breakers; for group lockout, the large bags (CAESAC) for electrical connectors complete the set. Check the shackle fit in the device and your procedure requirements before selecting these separately sold accessories. A tag does not replace the isolating device or energy verification.