Matrix EB100 contractor heater, 240/208 V

HEB100
$210.80

This item is not stocked. During the winter season, allow 5 to 7 days for delivery; off-season, contact us for the lead time.

Matrix EB100 fan-forced electric contractor heater, designed for industrial use and set on the floor. It delivers 4800 W (16,380 BTU/h) on 240 V or 3600 W on 208 V, and plugs into a NEMA 6-30R receptacle on a dedicated 30 A circuit. Built-in thermostat, high-temperature safety limit, permanently lubricated motor, handle with cord storage and 6 ft heavy-duty cord. Red cabinet, 1-year limited warranty. Not for household use.

Quantity

Return conditions:

No returnable if used. For more information about our return policy, please refer to the Orders and Returns.

Matrix EB100 electric contractor heater, 240/208 V, 4800 W with thermostat

This item is not stocked. During the winter season, allow 5 to 7 days for delivery; off-season, contact us for the lead time.

Manufacturer code (Matrix): EB100. This fan-forced industrial heater warms a shop, a garage or a building under construction when the main heating is not enough. On 240 V, it delivers 4800 W, or 16,380 BTU/h; on a 208 V supply, it delivers 3600 W. Its steel spiral fan, brazed to metal-sheathed elements, ensures maximum heat transfer, and its built-in thermostat cycles the unit on and off to maintain the desired temperature. It is designed to be set on the floor and is not intended for household or residential use.

Features of the Matrix EB100 contractor heater

  • 4800 W on 240 V or 3600 W on 208 V, 16,380 BTU/h on 240 V.
  • Built-in thermostat and high-temperature safety limit.
  • Steel spiral fan brazed to metal-sheathed elements.
  • Enclosed, permanently lubricated motor.
  • Carry handle with built-in cord storage.
  • 6 ft heavy-duty cord with NEMA 6-30P plug.
  • 1-year limited warranty.

Applications of the contractor heater

The EB100 serves as supplementary floor heating in shops, garages and buildings under construction or renovation that have a 240 V receptacle. To heat an office or a small household room on 120 V, choose instead the Matrix oscillating heater (HEA597) or the Matrix infrared heater (HEB184), restricted to household use.

Matrix EB100 heater technical specifications

FeatureDetail
ManufacturerMatrix Industrial Products
ModelEB100
TypeFan-forced industrial heater, floor use
Power supply240 V or 208 V AC, 60 Hz
Power4800 W on 240 V; 3600 W on 208 V
Output16,380 BTU/h
Amperage20 A
Required circuit240 V AC, 30 A, dedicated to the unit
Plug and receptacleNEMA 6-30P plug, NEMA 6-30R receptacle (250 V, 30 A)
CordHeavy-duty, 6 ft
ControlBuilt-in thermostat
Weight12 lb
Noise levelAround 55 dB
ColourRed
Country of originChina
Warranty1-year limited warranty

Connection and safe use

Before start-up, check that the receptacle is a grounded 240 V NEMA 6-30R receptacle, on a 30 A circuit dedicated to the unit: the heater draws 20 A. No adapter exists for this plug and none should be used; never remove the plug and do not use an extension cord. Set the unit on the floor on a stable surface, leave at least 5.5 in (14 cm) between its sides or rear and the walls, and keep combustible materials at least 3 ft (0.9 m) from the front and top. Do not use it outdoors, in a bathroom or a laundry area, or where gasoline, paint or flammable liquids are used or stored, and do not leave it running unattended for long periods.

Heater care and storage

Turn the thermostat off and unplug the unit before cleaning it. Remove interior dust with a vacuum cleaner and crevice tool, then wipe the cabinet with a soft, lightly damp cloth, without spraying liquid or wetting the heating element. If the overheat protection shuts the unit off, turn it off, unplug it, let it cool for 15 minutes and remove any object blocking airflow before plugging it back in. Off-season, store it clean and dry in a plastic bag, in a cool, dry place.

FAQ: Matrix EB100 contractor heater

What receptacle does this heater need?

A grounded 240 V NEMA 6-30R receptacle (250 V, 30 A), on a 30 A circuit dedicated to the unit. It does not plug into a regular 120 V outlet.

What is its power on 208 V?

It delivers 3600 W on a 208 V supply, and 4800 W (16,380 BTU/h) on 240 V.

Can it be used at home?

No. The manual states it is not for household or residential use: it is an industrial floor heater.

What should I do if the unit shuts off?

The overheat protection may have shut it off: unplug it, let it cool for 15 minutes, clear the surroundings, then plug it back in.

Does the heater have a thermostat?

Yes. The built-in thermostat cycles the unit on and off to maintain the chosen temperature.

Suggestions for shop or job site work in winter

For the shop or job site worker, plan for the foam nitrile-coated cut-resistant winter gloves (GS18WTFN) with waterproof membrane, the ParaActiv Pro™ touchscreen-friendly Kevlar (GSCXTAPVC) and steel knit cut-resistant winter gloves with PVC coating, the Showa Atlas latex gloves (G406XL) with acrylic lining, the 3M Solus clear anti-fog safety glasses (YAS1101) and the Ergodyne N-Ferno 6980 hand warmer muff (VNF6980). Also add Zenith hand warmers (VCHM20) and toe warmers (VCHO20).

For fire safety and emergencies near the heater, add the 10 lb ABC dry chemical portable extinguisher (EXABC10) with wall hook, the 20 lb ABC dry chemical portable extinguisher (EXABC20) for large areas, the emergency sign (EI700) “Extincteur incendie”, the Worksafe 6 V waterproof work light (LL03) and the first aid kit (TR03M) for 26 to 50 workers.

The texts coloured in green correspond to hyperlinks leading to specific safety equipment or to a general information link.

HEB100

Data sheet

Product group
Industrial products
Main category
Industrial accessories
Sub category
Winter products
Name of the product
Contractor heater
Product code
HEB100
Sort by keywords
Utility heaters
Product use
Industrial supplemental floor heating
Manufacturer
Matrix
Country of origin
China
Features
4800 W at 240 V or 3600 W at 208 V, 16,380 BTU/h
Additional Features
Handle with built-in cord storage
Voltage ratting
240 V or 208 V, 60 Hz
Maximum current
Maximum current 20 A
Cord length
6 ft / 1.83 m
Max Power consumption
4800 Watt
Material
Metal
Length (in/cm)
14.8 in / 37.59 cm
Width (in/cm)
12.3 in / 31.24 cm
Height (in/cm)
12 in / 30.4 cm
Weight (lb/kg)
12 lb / 5.4 kg
Sold by
Unit
Color
Red
Return conditions
No returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page
Warranty
1-year limited warranty
Caution
Indoor industrial floor use only
Heat output (BTU/h)
16,380 BTU/h
Noise level (dB)
Around 55 dB

Download

Matrix EB100 manual

Matrix EB100 heater instruction manual (English)

Download (237.59KB)

You might also like

Comments (0)
No customer reviews for the moment.