R60921

3M approved organic vapours combined cartridge for half & full face piece respirators series 6000, 7000 & FF-400. Sold in pairs.

$43.60

Return conditions : No returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page

3M NIOSH 42 CFR 84 approved combined P100 cartridge/filter for protection from organic vapours. These cartridges are compatible with 3M half facepiece and full facepiece respirators series 6000, 7000 and Ultimate-FX (FF-400). Sold in pairs, 30 pairs/case.

This type of cartridge has two indissolubly linked parts, that is, a P100 filter which protects one from airborne particles and an active charcoal part which protects one from gases and vapours. The filter is certified P100 which means it protects from 99,97% of solid, liquid, oil based and non-oil based particles in the air. The letter "P" stands for "oil proof". As for the active charcoal part, it is the most efficient and cost-efficient method of filtering airborne contaminants on the market. 3M 60921 cartridges have been design to protect one from organic vapours such as xylene, benzene, spray paint, pesticides and a myriad of other industrial solvents.

Use for:
This type of cartridge is ideal for chemical and petrochemical manufacturing, construction and transporation.

It protects from oil based particles, radioactive particles (uranium, plutonium), heavy metals particles (lead, cadmium, arsenic), and carcinogenic particles (4,4’-Methylenedianiline (MDA)). Certified "P100" filters protect one from silica, the second main cause of chronic respiratory problems after asbestos. CAUTION: 60921 cartridges don’t protect one from carbon monoxide (CO) and carbon dioxide (CO₂). If one has to work in an environment that may contain those two gases, one has to find another way to protect himself.

Biological particles:
This type of cartridges helps prevent the inhalation of certain airborne biological particles like mold, Bacillus anthracis (Anthrax), Mycobacterium tuberculosis (Tubercle bacillus Koch) the main causative agent of tuberculosis, pandemic flues (H5N1, H1N1), etc. However, it cannot eliminate the risk of contracting infection, illness or disease. Of course, whenever one has to protect himself only from biological particles, one should definitely opt for something else than this equipment. P100 cartridges are by design made for workers who must protect themselves from biological particles on top of being protected from gases, vapours and airborne particles.

Do not use for:
Do not use on a beard and other facial hair or if the user suffers from a condition that prevents him from having direct contact with the respirator’s sides. One should never use a respirator regardless of the type of cartridge in use whenever concentrations of gases and vapours exceed 10 times the admissible limit set by the CNESST or any other regulation applicable. Avoid sandblasting and oxygen deprived environments (an atmosphere with less than 19,5 % oxygen).

Maintenance and service life:
Studies have shown that in case of contaminant mixture, all vapours are absorbed simultaneously by the granulated charcoal inside the cartridges. One must take into account the presence of a contaminant mixture since the most volatile solvent will saturate the cartridge. The cartridge service life and one’s degree of protection will then depend on the concentration and the nature of the contaminants in the air.

Since this is a disposable product, there is no maintenance. In theory, whenever it is hard to breath with these cartridges, it means the filter part is saturated; one must thus change both cartridges. On the other hand, if one may smell and/or taste the contaminant from which he protects himself from, the charcoal part is saturated; one must thus change both cartridges again. The manufacturer’s limitations must be followed.

One may store its cartridges in an airtight bag or container since even when not in use, the cartridge absorb whatever contaminant there may be in the air.

Type of productSafety equipment
Main categoryPersonal protection
Sub categoryRespiratory protection
Sub sub category3M respirators and cartridges
Name of the productCartridge with P100 filter
Series of productsFor 7800S, FF-400, 7000, 5000, 7500, 6500, 6000 series respirators
Product codeR60921
Approved/CertifiedMeets NIOSH OV/P100
Manufacturer3M
Country of originUnited State of America
Maintenance freeDisposable product
Type of connectionBayonet type connector
Carbon filterWith carbon filter
Aerosol TypeOily and Non-Oily particles
Protection against gases and vaporsProtects against organic vapors + P100; against non oily or oily particles.
Useful life1825 Days
Cartridge color codeMagenta/Black
Material1Active charcoal
Material2Made with randomly arranged glass fibers
Material3Plastic
Length (in/cm)7.25 in / 18.4 cm
Width (in/cm)4.5 in / 11.43 cm
Height (in/cm)2 in / 5.08 cm
Weight (lb/kg)1 lb/ 0.45 Kg
Sold byPair
ColorMagenta/Black
Another packaging available160 units per case (30 pairs)
Another packaging available224 cases per pallet (1440 units-720 pairs)
Return conditionsNo returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page

Accessories

30 other products in the same category: