3M FT-15 fit test collar for sealing the FT-14 hood around the neck. Compatible with FT-30 and FT-10 apparatus. Compliant with OSHA 29 CFR 1910.134 and CSA Z94.4. Sold as a single unit.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
The 3M FT-15 Fit Test Collar is an essential component of the qualitative bitter (Bitrex) fit testing protocol. Used with the 3M FT-30 or FT-10 Qualitative Fit Test Apparatus, the FT-15 collar seals the bottom of the FT-14 test hood around the participant's neck, creating a closed environment in which the test solutions can be effectively nebulized. Its role is to ensure that the test agent remains concentrated around the participant's face throughout the test, in compliance with the requirements of OSHA 29 CFR 1910.134 and CSA Z94.4.
3M Manufacturer Code: 7000051789, model: FT-15
The FT-15 collar is compatible with the 3M FT-10 and FT-30 Qualitative Fit Test Apparatus. It is included in the complete FT-30 kit but can also be ordered separately to replenish the stock of an existing fit testing program. The collar provides an adjustable closure around the participant's neck to accommodate different body types. Sold as a single unit, it is designed for repeated use with proper cleaning between each use.
Inspect the FT-15 collar before each testing session for any signs of wear, tearing, or deformation that could compromise the hood seal. Clean the collar after each use according to the manufacturer's recommendations. Replace the collar if its integrity is compromised. Store it away from direct sunlight and extreme temperatures to preserve its elasticity and sealing properties.
Yes, the FT-15 collar is included in the 3M FT-30 Bitter Qualitative Fit Test Kit. If you already have an FT-30 or FT-10 apparatus and need to replace a worn or lost collar, the FT-15 can be ordered separately. It is designed to work exclusively with the 3M FT-10 and FT-30 qualitative fit test apparatus and ensures that the bottom of the FT-14 test hood is held snugly around the participant's neck throughout the entire test.
The FT-15 collar is designed for multiple uses, provided it is cleaned and inspected after each use. There is no maximum number of uses defined by the manufacturer, but the collar should be replaced as soon as signs of deterioration are observed: tearing, deformation, loss of elasticity, or any defect that could compromise the hood seal during the test. A defective collar could invalidate test results and unnecessarily expose the participant to risk.
Yes, the FT-15 collar is designed to work with the FT-14 test hood. The FT-14 hood is available separately under reference RFT14. Together, the FT-15 collar and the FT-14 hood create the closed test environment required for qualitative fit testing under OSHA 29 CFR 1910.134 and CSA Z94.4 protocols. Whether you are setting up a new fit testing program or replacing individual components, the collar and hood can be ordered separately or as part of the complete FT-30 kit.
To conduct fit testing in a safe work environment, equip the occupational health technician with powder-free class 2 medical nitrile gloves (PS706), SecureFit SF401 safety glasses with clear lenses (YASF401), 312 uncorded disposable earplugs (OA1250), a disposable white polyethylene apron (VT1281), and ambidextrous powder-free nitrile gloves 3.8 mils (GL7005). Under the "Accessories" tab at the bottom of the page, you will find the components directly related to fit testing: the complete FT-30 bitter kit (RFT30), the FT-32 fit test solution (RFT32), and the FT-31 sensitivity solution (RFT31).