The Bradley Halo wall-mounted eye and face wash PD19224T is designed to provide fast, effective, and safe emergency rinsing for the eyes and face in professional environments exposed to dust, particles, or hazardous substances. With its wall-mounted design, large activation handle, durable stainless steel bowl, and multi-stream spray heads, it is a reliable solution for laboratories, medical facilities, workshops, and industrial environments.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
Certified ANSI Z358.1-2009. Minimum flow exceeds 3.0 GPM (11.4 L/min). Does not include a device for controlling water temperature.
Ideal for laboratories, medical facilities, industries, workshops, and any other places where workers risk being exposed to dusts, particulates or dangerous materials.
This eye/face wash station is wall-mounted and keeps the floor area cleared. Its single-step activation simply requires a push on the large handle, leaving a user’s hands free once turned on. The sprayheads have an unique elongated design, with multiple water jets, that covers more area than traditional face wash sprayheads and facilitates face rinsing. This eye/face wash station is also barrier-free, for use by people in wheelchairs.
The eye wash station has separate pipes for water intake and drain, and ensures a safe, steady flow of water, even if the water supply pressure varies between 30 and 90 PSI. The bowl is made of heavy-duty stainless steel. The sprayheads are equipped with strainers to filter water particulates, and with an antimicrobial protection. Yellow and gray plastic caps protect the sprayheads from dust. Pipes are made of galvanized steel protected by yellow Bradtec covering.
The manufacturer recommends the installation of a thermostatic valve in order to comply with ANSI Z358.1-2009 standards. A thermostatic valve keeps rinsing water at a lukewarm temperature. Rinsing water should not be too cold (for more comfort while rinsing for the minimum required rinsing time of 15 minutes) nor too hot (to avoid aggravating eye or face injuries and to avoid scalding).
When an employee is exposed to contaminants affecting the eyes or face, rapid response is essential. This wall-mounted eye and face wash provides immediate access to emergency rinsing without taking up floor space. Its multi-stream spray design covers a wider surface area than many traditional face wash models, making facial rinsing easier while also providing effective eye flushing.
The PD19224T model is ANSI Z358.1-2009 approved and provides a minimum flow rate greater than 3.0 GPM (11.4 L/min) at 30 PSI. It can be used in laboratories, clinics, industrial settings, and other workspaces requiring compliant eye and face rinsing equipment. However, this model does not automatically control water temperature. The manufacturer therefore recommends adding a thermostatic valve to help maintain a proper flushing temperature during the minimum recommended 15-minute rinse period.
• Product code: PD19224T
• Brand: Bradley
• Manufacturer model: S19224T
• Type: wall-mounted eye and face wash
• Compliance: ANSI Z358.1-2009
• Minimum flow rate: greater than 3.0 GPM (11.4 L/min) at 30 PSI
• Compatible supply pressure: 30 to 90 PSI
• Activation: large handle allowing one-motion activation
• Accessibility: usable by people in wheelchairs
• Spray heads: multi-stream design for wider facial coverage
• Spray head construction: filters to retain water particles and antimicrobial protection
• Dust protection: yellow and grey plastic covers
• Bowl: durable stainless steel
• Piping: galvanized steel with yellow Bradtect coating
• Important feature: no automatic temperature control
• Key benefit: improved rinsing coverage for both eyes and face with a durable stainless steel bowl
• Install the unit securely on a wall according to the manufacturer’s instructions.
• Connect the assembly to a compatible water supply.
• In an emergency, activate the unit by pushing the large handle.
• Position the eyes and face in the spray to begin rinsing immediately.
• Continue flushing according to applicable safety procedures and, whenever possible, confirm that the water temperature remains suitable.
• Regularly inspect the spray heads, covers, bowl, and piping.
• Clean the nozzles and components to prevent residue buildup.
• Make sure the unit remains unobstructed and ready for use at all times.
• Periodically check the flow rate and overall condition of the system.
• Replace worn or damaged parts to maintain reliable operation.
Yes. Its multi-stream spray design provides wider coverage, making it easier to rinse the face while also effectively flushing the eyes.
Yes. It is designed for laboratories, medical environments, workshops, industries, and other workspaces where rapid eye and face rinsing is required.
No. This model does not include a thermostatic valve, so the manufacturer recommends adding one to improve flushing comfort and safety.
Check out: eyewash sign (ECU505-812), rigid eye shield (PS511), sterile eye pads (PS514), Cederroth emergency eyewash solution (PD505-235), 1-litre wall-mounted eyewash station (PD520), wall bracket for Cederroth eyewash solution (PD505S), hearing protection earplugs (OA101), and N95 respirator mask (R8210). See the “Accessories” tab at the bottom of the page.