The Bradley Halo wall-mounted eyewash PD19224PDC is designed to provide fast, effective, and safe emergency eye rinsing in professional environments exposed to dust, particles, or hazardous substances. With its wall-mounted design, large activation handle, impact-resistant plastic bowl, and integrated dust cover, it is a reliable solution for laboratories, medical facilities, workshops, and industrial environments.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
Designed with a plastic bowl and dust cover, this eye wash station ensures optimal protection in the event of chemical accidents. Compliant with ANSI Z358.1-2009 standards, it guarantees reliable and efficient performance. Easy to install, it provides a quick response for eye rinsing, ensuring the safety and well-being of your employees.
Certified ANSI Z358.1-2009. Minimum flow exceeds 0.4 GPM (1.5 L/min). It does not include a device for controlling water temperature.
Ideal for laboratories, medical facilities, industries, workshops, and any other places where workers risk being exposed to dust, particulates or dangerous materials.
This eye wash station is wall-mounted and keeps the floor area cleared. Its single-step activation simply requires a push on the large handle, leaving a user’s hands free once turned on. The hinged dust cover tilts open at the same time as the handle moves. This eye wash station is also barrier-free, for use by people in wheelchairs.
The eye wash station has separate pipes for water intake and drain, and ensures a safe, steady flow of water, even if the water supply pressure varies between 30 and 90 PSI. The bowl is made of yellow impact-resistant plastic. The spray heads are equipped with strainers to filter water particulates, and with antimicrobial protection. Pipes are made of galvanized steel protected by a yellow Bradtec covering.
The manufacturer recommends the installation of a thermostatic valve in order to comply with ANSI Z358.1-2009 standards. A thermostatic valve keeps rinsing water at a lukewarm temperature. Rinsing water should not be too cold (for more comfort while rinsing for the minimum required rinsing time of 15 minutes) nor too hot (to avoid aggravating eye or face injuries and to avoid scalding).
Make safety a priority.
When an employee is exposed to eye contaminants, rapid response is essential. This wall-mounted eyewash provides immediate access to emergency rinsing without taking up floor space. Its one-motion activation, which leaves both hands free afterward, helps improve workplace safety and ease of response in environments where exposure risks are real.
The PD19224PDC model is ANSI Z358.1-2009 approved and provides a minimum flow rate greater than 0.4 GPM (1.5 L/min) at 30 PSI. It can be used in laboratories, clinics, industrial settings, and other workspaces requiring a compliant emergency eyewash. However, this model does not automatically control water temperature. The manufacturer therefore recommends adding a thermostatic valve to help maintain a proper flushing temperature during the minimum recommended 15-minute rinse period.
• Product code: PD19224PDC
• Brand: Bradley
• Type: wall-mounted eyewash
• Compliance: ANSI Z358.1-2009
• Minimum flow rate: greater than 0.4 GPM (1.5 L/min) at 30 PSI
• Compatible supply pressure: 30 to 90 PSI
• Activation: large handle allowing one-motion activation
• Accessibility: usable by people in wheelchairs
• Spray head construction: filters to retain water particles and antimicrobial protection
• Dust protection: yellow plastic dust cover
• Bowl: yellow impact-resistant plastic
• Important feature: no automatic temperature control
• Key benefit: improved spray-head protection thanks to the integrated dust cover
• Install the unit securely on a wall according to the manufacturer’s instructions.
• Connect the assembly to a compatible water supply.
• In an emergency, activate the eyewash by pushing the large handle.
• Position the eyes in the spray to begin flushing immediately.
• Continue rinsing according to applicable safety procedures and, whenever possible, confirm that the water temperature remains suitable.
• Regularly inspect the spray heads, covers, bowl, and piping.
• Clean the nozzles and components to prevent residue buildup.
• Make sure the dust cover remains in good condition to protect the spray heads effectively.
• Periodically check the flow rate and overall condition of the system.
• Replace worn or damaged parts to maintain reliable operation.
Yes. It is designed for laboratories, medical environments, workshops, industries, and other workspaces where rapid eye rinsing is required.
It helps protect the spray heads from dust and contaminants when the unit is not in use, which helps keep the equipment ready for use.
No. This model does not include a thermostatic valve, so the manufacturer recommends adding one to improve flushing comfort and safety.
Check out the following items: CDN Eye Wash Poster (ECU505), rigid plastic eye patches, 7.5 X 1.25 X 3.8 cm (PS511), sterile eye pads, 4.1 X 6.6 cm (PS514), Cederroth emergency eye wash solution (PD505), wall-mounted eye wash kit, 1 liter (PD520), wall mount for Cederroth eye wash solution (PD505S).
Under “Accessories” at the bottom of the page. If you're looking for work equipment, see the following products: Earplugs (OA101) and 3M N95 respirators (R8210).