3M Secure Click Hard Case P100 Filter D9093C, HF, OV/AG

3M Secure Click Hard Case P100 Filter D9093C, HF, OV/AG. NIOSH approved, class P100; hydrogen fluoride. Sold as: pair (2 filters). Attaches only to the Secure Click HF-800 reusable half-mask (RHF80XSD) and the Secure Click FF-800 reusable full facepiece (RFF800).

Quantity

Return conditions:

No returnable if used. For more information about our return policy, please refer to the Orders and Returns.

3M Secure Click Hard Case P100 Filter D9093C, HF, OV/AG

3M manufacturer code: 7100206890, model D9093C

This filter from the 3M Secure Click range carries the full name « 3M Secure Click Hard Case Particulate Filter D9093C, P100, with Hydrogen Fluoride and Nuisance Level Organic Vapor/Acid Gas Relief ». It offers: NIOSH class P100; NIOSH approved against: hydrogen fluoride; nuisance level organic vapors, acid gases relief (3M recommendation). Sold as: pair (2 filters).

It attaches exclusively to 3M Secure Click facepieces: the Secure Click HF-800 reusable half-mask (RHF80XSD) and the Secure Click FF-800 reusable full facepiece (RFF800).

Key features of the 3M Secure Click D9093C

  • NIOSH class: P100
  • Approved gases and vapours: hydrogen fluoride
  • Nuisance levels (3M recommendation): organic vapors, acid gases
  • Secure Click connection: clicks onto HF-800 and FF-800 facepieces
  • Sold as: Pair (2 filters)

Secure Click compatibility

3M Secure Click facepieces only: HF-800 half facepieces (HF-801, HF-802, HF-803, HF-801SD, HF-802SD, HF-803SD) and FF-800 full facepieces (FF-801, FF-802, FF-803).

Limitations and safe use

  • NIOSH approved with 3M Secure Click facepieces. Do not use in atmospheres immediately dangerous to life or health (IDLH) or in oxygen-deficient atmospheres.
  • Establish a cartridge change schedule and replace the cartridges no later than when the odour or taste of the contaminant is detected.
  • Nuisance levels: concentrations that do not exceed the OSHA permissible exposure limit (PEL) or the lowest applicable exposure limit. This relief is a 3M recommendation, without NIOSH approval for these gases and vapours.
  • Ozone: 3M recommends it up to 1 ppm, for a maximum of 8 hours. This is a manufacturer recommendation, not a NIOSH approval.
  • Use within a respiratory protection program that meets CSA Z94.4; read the 3M user instructions before use.

Filter replacement

Replace the filters when they are damaged, soiled or when breathing becomes difficult. Always replace both filters at the same time.

Technical specifications

Product codeRD9093C
Manufacturer3M
ApprovalNIOSH approved, class P100; hydrogen fluoride
Sold asPair (2 filters)
Country of originCanada

FAQ about the 3M Secure Click D9093C

Which facepieces does it fit?

Only with 3M Secure Click facepieces: HF-800 half facepieces and FF-800 full facepieces.

What does it protect against?

NIOSH approved against: hydrogen fluoride. Nuisance level organic vapors, acid gases relief, per the 3M recommendation (not NIOSH approved).

How is it sold?

Sold as: Pair (2 filters).

When should the filter be replaced?

When it is damaged, soiled or when breathing becomes difficult.

What does the NIOSH class mean?

N means not resistant to oil, P means oil resistant; 95 or 100 indicates filtration efficiency.

Complementary suggestions for respiratory protection

For sanding, grinding or sawing where particles are the main hazard, complete your equipment with safety eyewear (YAS1101), noise-reducing earplugs (OA3001), reusable gloves (GN230FL), another model of gloves (G523) and noise-reducing earmuffs (OPHY7).

This filter is used with Secure Click facepieces: the Secure Click HF-800 reusable half-mask (RHF80XSD) and the Secure Click FF-800 reusable full facepiece (RFF800), as well as other products in the same range: the D3091 P100 filter (RD3091), the D80923 organic vapour and acid gas cartridge/filter, P100 (RD80923) and the D3096 P100 filter with nuisance level acid gas relief (RD3096).

The texts coloured in green correspond to hyperlinks leading to specific safety equipment or to a general information link.

RD9093C

Data sheet

Product group
Safety equipment
Main category
Personal protection
Sub category
Respiratory protection
Sub sub category
3M respirators and cartridges
Name of the product
P100 particle filters
Product code
RD9093C
Product use
Particulate filter
Approved/Certified
NIOSH approved, class P100; hydrogen fluoride
Manufacturer
3M (TM)
Country of origin
Canada
Feature that facilitates use
Clicks onto Secure Click HF-800 and FF-800 facepieces (audible click)
Type of connection
Secure Click connection
Nuisance Odour Relief (< OSHA PEL)
Nuisance levels (3M recommendation): organic vapors, acid gases
Protection against gases and vapors
Protects against: hydrogen fluoride, particulates (P100)
Cartridge color code
Magenta/olive
Length (in/cm)
2.7 in / 6.9 cm
Width (in/cm)
4.7 in / 11.94 cm
Height (in/cm)
2.8 in / 7.11 cm
Weight (lb/kg)
0.275 lb / 0.125 kg (packed: pair (2 filters))
Sold by
Pair (2 filters)
HS Code
9020000000
Return conditions
No returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page

Download

directives_D9000_P100

User instructions - Secure Click D9000 P100 filters (3M)

Download (297.83KB)

guide_selection_respirateurs_FR

3M respirator selection guide (French)

Download (3.7MB)

guide_selection_respirateurs_EN

3M respirator selection guide (English)

Download (824.97KB)

bulletin_ozone_3M

3M technical bulletin - respiratory protection for ozone

Download (142.01KB)

You might also like

Comments (0)
No customer reviews for the moment.