The Bradley Halo pedestal eyewash PD19214B is designed to provide fast, effective, and safe emergency eye rinsing in professional environments exposed to dust, particles, or hazardous substances. With its pedestal-mounted design, large activation handle, and durable stainless steel bowl, it is a reliable solution for laboratories, medical facilities, workshops, and industrial environments.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
Featuring a durable stainless steel bowl, it ensures quick and efficient eye decontamination in case of chemical or thermal accidents. Complying with ANSI Z358.1-2009 standards, this eyewash station guarantees maximum protection, allowing your employees to work with peace of mind. Its innovative and robust design makes it a reliable choice for any workplace requiring enhanced safety.
Certified ANSI Z358.1-2009. Minimum flow exceeds 0.4 GPM (1.5 L/min). It does not include a device for controlling water temperature.
Ideal for laboratories, medical facilities, industries, workshops, and any other places where workers risk being exposed to dust, particulates or dangerous materials.
This eye wash station is wall-mounted and keeps the floor area cleared. Its single-step activation simply requires a push on the large handle, leaving a user’s hands free once turned on. This eye wash station is also barrier-free, for use by people in wheelchairs.
The eye wash station has separate pipes for water intake and drain, and ensures a safe, steady flow of water, even if the water supply pressure varies between 30 and 90 PSI. The bowl is made of heavy-duty stainless steel. The spray heads are equipped with strainers to filter water particulates, and with antimicrobial protection. Yellow plastic caps protect the spray heads from dust. Pipes are made of galvanized steel protected by a yellow Bradtec covering.
The manufacturer recommends the installation of a thermostatic valve in order to comply with ANSI Z358.1-2009 standards. A thermostatic valve keeps rinsing water at a lukewarm temperature. Rinsing water should not be too cold (for more comfort while rinsing for the minimum required rinsing time of 15 minutes) nor too hot (to avoid aggravating eye or face injuries and to avoid scalding).
Make safety a priority.
When an employee is exposed to eye contaminants, rapid response is essential. This pedestal eyewash provides immediate access to emergency rinsing without relying on a wall-mounted installation. Its freestanding configuration is especially useful in large workshops, laboratories, and open work areas where the equipment must be positioned away from walls. Its one-motion activation, which leaves both hands free afterward, helps improve workplace safety and ease of response.
The PD19214B model is ANSI Z358.1-2009 approved and provides a minimum flow rate greater than 0.4 GPM (1.5 L/min) at 30 PSI. It can be used in laboratories, clinics, industrial settings, and other workspaces requiring a compliant emergency eyewash. However, this model does not automatically control water temperature. The manufacturer therefore recommends adding a thermostatic valve to help maintain a proper flushing temperature during the minimum recommended 15-minute rinse period.
• Product code: PD19214B
• Brand: Bradley
• Manufacturer model: S19214B
• Type: pedestal eyewash
• Compliance: ANSI Z358.1-2009
• Minimum flow rate: greater than 0.4 GPM (1.5 L/min) at 30 PSI
• Compatible supply pressure: 30 to 90 PSI
• Activation: large handle allowing one-motion activation
• Accessibility: usable by people in wheelchairs
• Spray head construction: filters to retain water particles and antimicrobial protection
• Dust protection: yellow plastic dust covers
• Bowl: durable stainless steel
• Piping: galvanized steel with yellow Bradtect coating
• Important feature: no automatic temperature control
• Key benefit: pedestal configuration combined with a durable stainless steel bowl
• Secure the unit firmly to the floor according to the manufacturer’s instructions.
• Connect the assembly to a compatible water supply.
• In an emergency, activate the eyewash by pushing the large handle.
• Position the eyes in the spray to begin flushing immediately.
• Continue rinsing according to applicable safety procedures and, whenever possible, confirm that the water temperature remains suitable.
• Regularly inspect the spray heads, covers, bowl, and piping.
• Clean the nozzles and components to prevent residue buildup.
• Make sure the unit remains unobstructed and ready for use at all times.
• Periodically check the flow rate and overall condition of the system.
• Replace worn or damaged parts to maintain reliable operation.
Yes. Its pedestal design makes it especially useful in larger work areas where installation should not be limited by wall proximity.
It provides excellent durability, strong wear resistance, and longer service life in demanding professional environments.
No. This model does not include a thermostatic valve, so the manufacturer recommends adding one to improve flushing comfort and safety.
Check out the following items: CDN Eye Wash Poster (ECU505), rigid plastic eye patches, 7.5 X 1.25 X 3.8 cm (PS511), sterile eye pads, 4.1 X 6.6 cm (PS514), Cederroth emergency eye wash solution (PD505), wall-mounted eye wash kit, 1 liter (PD520), wall mount for Cederroth eye wash solution (PD505S).
Under “Accessories” at the bottom of the page. If you're looking for work equipment, see the following products: Earplugs (OA101) and 3M N95 respirators (R8210), safety glasses (YASF401).
Data sheet