5 lb vehicle-rated ABC dry chemical portable fire extinguisher, ULC 3A-40BC rated, monoammonium phosphate agent, vehicle hook. For class A, B and C fires.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
The 5 lb vehicle-rated ABC dry chemical portable fire extinguisher is rated ULC 3A-40BC, with increased capacity on flammable-liquid fires (class B). Designed to fight class A, B and C fires, it comes with a vehicle hook, ideal for trucks, machinery and transport.
The extinguishing agent is a monoammonium phosphate dry chemical (yellow powder), effective on the three targeted fire classes. The red steel body is coated with a weather-resistant baked polyester enamel finish, and the cylinder has passed a pressure-resistance test.
Agent type: ABC dry chemical (monoammonium phosphate).
Capacity: 5 lb.
ULC rating: 3A-40BC.
Approval: ULC.
Discharge range: 8 to 10 ft (2.5 to 3 m).
Discharge time: 13 secondes.
Operating temperature: -54°C à +49°C (-65°F à +120°F).
Weight: 11 lb (5 kg).
Manufacturer model: Strike First SF-ABC340.
This extinguisher is recommended for class A fires (wood, paper, fabric), class B fires (flammable liquids and gases) and can be used on energized electrical equipment (class C).
Electrical fires: immediately cut the circuit power before extinguishing the fire.
Class D: do not use on combustible-metal fires (class D).
An extinguisher only protects you if it is kept in good condition. Regular maintenance ensures it will work the day you need it.
Monthly visual inspection: check that the gauge needle is in the green zone, that the pin and tamper seal are in place, and that the unit is not damaged, corroded or obstructed.
Annual servicing: have the extinguisher inspected yearly by a certified technician, in accordance with the applicable standard (NFPA 10 / local regulations).
Recharge: any extinguisher that has been used, even partially, must be recharged immediately by a qualified shop.
Hydrostatic test: the cylinder must undergo periodic pressure testing per the standard, then be replaced at the end of its service life.
Location: keep the extinguisher accessible, clearly marked and protected from weather and impact.
The ULC rating indicates extinguishing capacity: the number before the "A" relates to solid-material fires, and the number before "BC" the area of flammable-liquid fire the unit can control. Higher numbers mean greater capacity.
On class A fires (wood, paper, fabric), class B fires (flammable liquids and gases) and energized electrical equipment (class C). Never use it on combustible metals (class D).
Visual inspection every month and annual servicing by a certified technician. After any use, the extinguisher must be recharged without delay.
For complete fire protection, equip each at-risk area with an extinguisher matched to its capacity, mount it correctly and clearly mark it. Sylprotec offers the full range of portable extinguishers, brackets and cabinets to build a coherent setup.
Sylprotec also offers an inspection and maintenance service for portable extinguishers in the greater Montreal area, plus a full range of fire-protection signs to reduce reaction time.
See also a compact 2.5 lb size (EXABC2.5), a 10 lb model (EXABC10), a 20 lb version (EXABC20), a wall hook for 5 lb (CDM5), a vehicle bracket for 5 lb (CUNV5), a semi-recessed cabinet (EC5), an extinguisher-location sign (EI700) and the 3A-10BC standard model (EXABC5). Under "Accessories" at the bottom of the page.