compare_arrows

3M Speedglas 9100 FX-Air air duct assembly 26-0400-55

Reference : R26-0400-55
$334.15

This item is not stocked. Allow 48 days for delivery.

The 3M Speedglas 26-0400-55 duct assembly carries breathable air from the Adflo unit or air supply tube into 9100 FX-Air helmets. Its length adjusts to the welder, and a new duct restores a steady flow when the old one leaks or distorts. Black part sold individually, distinct from the 9100-Air duct. It feeds the diffuser (R06-0700-85) of the same helmet.

Quantity

Compare

3M Speedglas 9100 FX-Air air duct assembly 26-0400-55

3M manufacturer code: 7000128095, model 26-0400-55

This item is not stocked. Allow 48 days for delivery.

The 3M Speedglas 26-0400-55 duct assembly carries breathable air into 9100 FX-Air welding helmets. It connects the breathing tube of the Adflo unit or the breathable air supply to the inside of the helmet, and its length adjusts to the welder's preference. A cracked, distorted or leaking duct loses part of the flow: replacing it restores a steady air supply, and with it the intended comfort and respiratory protection. Genuine black part sold individually, specific to the 9100 FX-Air and distinct from the 25-0400-55 duct of the 9100-Air.

Routing air inside the 9100 FX-Air helmet

  • Carries breathable air from the breathing tube into the helmet.
  • Length adjustable to the welder's preference.
  • Genuine part of the 9100 FX-Air helmet.
  • Restores a steady air flow when the old duct leaks or distorts.
  • Distinct from the 25-0400-55 duct of the 9100-Air helmet.

Replacing the air duct in the welding respirator

The duct is used to maintain 9100 FX-Air helmets used with an Adflo powered air-purifying unit or a breathable air supply, in metal fabrication, construction, industrial maintenance and heavy infrastructure projects. It accompanies welding, grinding and assembly at stations where welding fume calls for respiratory protection.

Connecting the diffuser and Adflo breathing tube

On the 9100 FX-Air helmet, the 26-0400-55 duct feeds the diffuser (R06-0700-85) and works with the face seal (R26-0099-28). On the unit side, it connects to a breathing tube such as the noise-reducing tube (RSG-50W).

Inspecting the duct for cracks and leaks

Before use, check that the duct and tube are undamaged and do not leak air. After use, wipe the helmet with a damp cloth, without rinsing, immersing or using solvents. Replace the duct if it is damaged, distorted or leaking.

Speedglas air duct assembly specifications

  • Features : Respiratory protection accessories
  • Product colour : Black
  • Recommended industries : Construction ; Heavy infrastructure ; Industrial maintenance
  • Compatible welding helmet : 9100 FX-Air welding helmets
  • Product series : FX-Air 9100
  • Welding : Yes
  • Product type : Air duct assemblies
  • Recommended applications : Assembly ; Sanding ; Welding ; Facility maintenance ; Grinding ; Machine operation
  • For use with : Speedglas 9100 FX-Air welding helmets

FAQ about the 9100 FX-Air air duct

Does this duct fit the 9100-Air helmet?

No. The 9100-Air uses the 25-0400-55 duct; the 26-0400-55 is specific to the 9100 FX-Air.

Is the breathing tube included?

No. The tube is chosen separately according to the unit used.

Can its length be adjusted?

Yes. 3M states that the duct length adjusts to the welder's preference.

How do I know it needs changing?

A damaged, distorted or leaking duct must be replaced.

How should it be cleaned?

Wipe with a damp cloth, without rinsing, immersion or solvents.

Suggestions for maintaining the Adflo air circuit

The FX-Air helmet receives its air from the Adflo; the welder adds foam-sealed Virtua Max glasses (YA11872) under the visor and Endura goatskin and Kevlar gloves (G625). Blue flame-resistant ARC 2 coveralls (V1766), metatarsal guards (VCMET) on the boots and the earmuff (OH505B) complete the outfit.

To maintain the same system, you can refer to filter (R15-0299-2) : 3M Adflo High-Efficiency Particulate Filter, Pack of 2 Units. You can also refer to hose (RSG-50W) : 3M Speedglas Noise-Reducing Breathing Tube for Adflo PAPR. You can also refer to battery (R35-1099-07) : 3M Adflo Lithium-Ion Battery for PAPR Respirator. You can also refer to diffuser (R06-0700-85) : 3M Speedglas 9100 FX-Air air diffuser. You can also refer to seal (R26-0099-28) : 3M Speedglas 9100 FX-Air face seal.

The texts coloured in green correspond to hyperlinks leading to specific safety equipment or to a general information link.

R26-0400-55

Data sheet

Product group
Safety equipment
Main category
Personal protection
Sub category
Respiratory protection
Sub sub category
Adflo Welding Respirators by 3M
Name of the product
Welding helmet air duct
Series of products
Speedglas 9100
Product code
R26-0400-55
Sort by keywords
Face masks & cartridges
Product use
For welding work
Manufacturer
3M (TM)
Country of origin
Sweden
Features
Air duct for Speedglas 9100 FX-Air helmets only (9100-Air: 25-0400-55)
Includes
One 26-0400-55 air duct assembly
Length (in/cm)
13.2 in / 33.53 cm
Width (in/cm)
6.8 in / 17.27 cm
Height (in/cm)
5.9 in / 14.99 cm
Weight (lb/kg)
0.7 lb / 0.3 kg
Availability
Please note: Available only on special order
Sold by
Unit
Color
Black
HS Code
9020000000
Care and maintenance
Check for damage and leaks before use; wipe with a damp cloth without rinsing or solvents; replace if leaking or distorted.
Return conditions
Not returnable if used
Speedglas product type
Breathing tubes, covers and air ducts
Respiratory protection product type
PAPR and welding replacement parts

Specific References

UPC
051131497245
MPN
26-0400-55

You might also like

Comments (0)
No customer reviews for the moment.