compare_arrows
  • New
Battery fastening tool 3M Versaflo TR-838
search
  • Battery fastening tool 3M Versaflo TR-838

Battery fastening tool 3M Versaflo TR-838

RVTR838
$24.85

This item is not kept in stock. Please allow 30 days for delivery.

The 3M Versaflo TR-838 tool secures the battery to the blower in the TR-800 series. Supplied with two screws, it supports the prescribed assembly operation without including a battery, blower or standalone tool certification.

Quantity

Return conditions:

No returnable if used. For more information about our return policy, please refer to the Orders and Returns.

Battery fastening tool 3M Versaflo TR-838

3M manufacturer code: 7100150921, model TR-838

This item is not kept in stock. Please allow 30 days for delivery.

The 3M Versaflo TR-838 fastening tool supports a specific TR-800 assembly step: securing the TR-830 battery to the TR-802N blower. It serves the station where teams prepare and check equipment before painting, finishing or welding. The sales unit includes the tool and two screws, without a battery or filtering element. Its role remains tied to the assembly fastening procedure without assigning the complete respiratory system's safety properties to the tool alone.

Features and function of the tool

  • TR-838 tool is intended for battery fastening.
  • Used with the TR-830 battery in the intended assembly.
  • Matching blower: TR-800 series TR-802N.
  • One tool and two screws per sales unit for the equipment preparation station.
  • Assembly function is distinct from electrical power and filtration.

Compatibility and system integration

The TR-838 secures TR-830 to TR-802N. Fastening must follow the TR-800 system procedure and does not make another battery compatible. The tool is supplied with two screws, without a battery or blower.

Applications at the respirator preparation station

In paint, composite finishing or welding shops, this tool belongs to TR-800 system preparation equipment. Use it during battery assembly before respirator checks. It is not a production tool for painting or welding and does not change the respiratory configuration's use limitations.

Setup and battery fastening

Identify the TR-802N blower and TR-830 battery before using the TR-838 tool. Change the battery only in a location known to be non-hazardous. Never bring a battery alone into a potentially flammable or explosive area. Apply the 3M fastening procedure for this assembly, then check battery retention. Do not add a tightening or modification method absent from the system instructions.

Tool specific limitations

Fastening is a system assembly step rather than standalone TR-838 certification. This tool produces no air, does not charge the battery and filters no contaminant. Complete system selection and operating conditions must still be checked separately.

Care, inspection and replacement

Inspect tool condition before fastening. Do not use a damaged tool to improvise assembly; replace it and check fastening elements according to 3M instructions. Keep it with preparation equipment so it is available when changing the battery. After assembly, perform the required battery and blower checks before returning the system to service.

FAQ: the TR-838 battery fastening tool

Is the TR-838 a replacement battery?

No. It is the tool used to secure the TR-830 battery to the TR-802N blower.

Which blower matches the tool?

The specified assembly pairs TR-802N and TR-830 battery in the TR-800 series.

Is a battery supplied with the tool?

No. The order includes the TR-838 tool and two screws. Battery and blower are separate.

Does having the tool alone approve the system?

No. Battery fastening and all components must follow the complete configuration instructions.

What should be checked after fastening?

Verify battery retention and then complete the 3M prescribed system checks before use.

Complementary suggestions

For an equipment preparer using the battery tool before dispatch, plan Dexterity gloves (GSSXPU3OF) with three open fingers for appropriate handling tasks. Privo glasses (YA12264) with mirror lenses serve outdoor movement outside the headgear. The mask (R8576) with Cool Flow valve concerns a separate respiratory task according to exposure. Yellow hook and loop armbands (VS15) and a yellow manhole collar (EPTBBT) complete movement and technical access preparation according to the task.

The blower (RVTR802N) receives the TR-830 battery secured with this tool. To prepare TR-800 equipment rather than an individual part, review separately the durable (RVTR813) belt assembly, easy clean (RVTR800ECK) kit, painter (RVTR800PSK) kit or heavy industry (RVTR800HIK) kit. These are separate configurations selected according to work rather than added to the blower alone.

The texts coloured in green correspond to hyperlinks leading to specific safety equipment or to a general information link.

RVTR838

Data sheet

Product group
Safety equipment
Main category
Personal protection
Sub category
Respiratory protection
Sub sub category
3M Versaflo TR-800 Powered Air-Purifying Respirators
Name of the product
Respiratory Accessories
Series of products
Versaflo (Mc) TR-800
Product code
RVTR838
Sort by keywords
Face masks & cartridges
Product use
Respiratory protection
Manufacturer
3M (TM)
Country of origin
United States of America
Features
Compatible with the TR-830 battery and TR-802N blower
Material
Not disclosed by the manufacturer
Length (in/cm)
5.75 in / 14.60 cm
Width (in/cm)
7.5 in / 19.05 cm
Height (in/cm)
0.25 in / 0.64 cm
Weight (lb/kg)
0.011 lb / 0.0049 kg
Sold by
Unit
Color
Black
HS Code
8204110090
Return conditions
Not returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page
Caution
No certification specific to the tool
Respiratory protection product type
Batteries and chargers

You might also like

Comments (0)
No customer reviews for the moment.