- New
This item is not kept in stock. Please allow 20 days for delivery.
The 3M Versaflo TR-611N kit prepares a TR-600 tight fitting facepiece configuration with the BT-63 tube, TR-630 standard battery and TR-627 belt. The facepiece and filter or cartridge are not included. charger included.
No returnable if used. For more information about our return policy, please refer to the Orders and Returns.
3M manufacturer code: 7100176756, model TR-611N
This item is not kept in stock. Please allow 20 days for delivery.
The 3M Versaflo TR-611N kit is distinguished by its BT-63 breathing tube for tight fitting facepieces. It combines the TR-602N blower, a standard battery and an easy clean belt to prepare powered air delivery to the selected mask. In automotive shops, maintenance or pharmaceutical production, this base lets filtration be selected for the task. Add the facepiece and filter or cartridge before building the complete system.
This base brings together the BT-63 tube, TR-602N blower and TR-630 battery with the TR-627 waist belt. It suits a setup where the tight fitting facepiece and filtration will be chosen separately. The TR-642N charger is included to arrange charging.
This assembly supports tasks such as assembly, general maintenance and painting in automotive, pharmaceutical and healthcare settings. In a spray booth or during maintenance, filtration and facepiece selection must match the contaminants and authorized configuration. The BT-63 tube calls for a tight fitting facepiece rather than an S-series hood.
No filter or cartridge is supplied; do not assume protection against any gas, vapour or particulate before selecting the complete configuration. The powered system supplies no oxygen and is unsuitable where oxygen is deficient. This configuration is not intrinsically safe and must not be used in an explosive atmosphere. Have another approved solution selected when the hazard requires it. A cartridge cannot replace an appropriate breathing supply where oxygen is deficient.
| Component | 3M code | Sylprotec code |
|---|---|---|
| Blower | TR-602N | blower (RVTR602N) |
| Standard battery | TR-630 | battery (RVTR630) |
| Single station charger | TR-642N | RVTR642N |
| Tight fitting breathing tube | BT-63 | tube (RBT63) |
| Easy clean belt | TR-627 | belt (RVTR627) |
| Airflow indicator for BT-63/BT-64 | TR-973 | |
| Spark arrestor | TR-662 | screen (RVTR662) |
| Prefilter | TR-6600 | prefilter (RVTR6600) |
| Breathing tube storage plugs | BT-957 |
Buy separately: a tight fitting facepiece and filter or cartridge approved for the selected assembly.
Selection within the Versaflo TR-600 range must account for the tight fitting facepiece and BT-63 tube. The facility program governs filtration choice, assembly and checks before entry into the exposure area. Also prepare the care accessories appropriate to this equipment.
One TR-600 series kit with a standard lithium-ion battery and waist mounting. Stated run time is 8 hours. NIOSH approval requires the complete approved combination of facepiece, tube, filtration and power supply. The TR-973 is intended for checking the BT-63/BT-64 tube.
Inspect the BT-63 and its connections, belt and battery, then perform the required check with the TR-973. BT-957 storage plugs accompany the tube. To immerse the TR-600 blower, remove the filter and tube and follow only the 3M procedure with the appropriate cleaning plugs. Other components, including the battery, follow their own instructions. Store the assembly after cleaning and replace damaged parts before using it again.
Not in this assembly. The BT-63 is intended for tight fitting facepieces. Choose the facepiece specified in the corresponding 3M combination.
Yes. The TR-611N contains neither a filter nor a cartridge. Select them for the contaminants and complete configuration.
The TR-630 battery comes with the TR-642N single station charger, Sylprotec code RVTR642N.
The supplied TR-973 is intended for the BT-63/BT-64 tube. Use it according to the checking instructions for this configuration.
Yes, BT-957 plugs are included. They accompany the tube for storage and do not replace the plugs required for blower cleaning.
For a mechanic preparing the tight fitting mask before maintenance, plan Endura Pro gloves (G378GKGVBE) designed for cuts and impacts during handling. Clear anti-fog Solus glasses (YAS1101) support checks outside the mask, and cordless Laser Lite earplugs (OA1101) are selected according to shop noise. A pink women's 9-pocket vest (V139FRO) organizes light tools, while yellow Danger tape (ECT3YE7) reserves the maintenance station.
For TR-611N replacements, plan the TR-602N blower (RVTR602N), TR-630 standard battery (RVTR630) and BT-63 tube (RBT63) for a tight fitting facepiece. The TR-627 belt (RVTR627), TR-6600 prefilter (RVTR6600) and TR-662 spark arrestor screen (RVTR662) match supplied components. Request the TR-642N charger, code RVTR642N, and BT-957 plugs by model. Complete the setup separately with the facepiece and filtration in the approved combination.